]> git.kernelconcepts.de Git - karo-tx-linux.git/blob - drivers/auxdisplay/Kconfig
Merge branch 'x86-urgent-for-linus' of git://git.kernel.org/pub/scm/linux/kernel...
[karo-tx-linux.git] / drivers / auxdisplay / Kconfig
1 #
2 # For a description of the syntax of this configuration file,
3 # see Documentation/kbuild/kconfig-language.txt.
4 #
5 # Auxiliary display drivers configuration.
6 #
7
8 menuconfig AUXDISPLAY
9         bool "Auxiliary Display support"
10         ---help---
11           Say Y here to get to see options for auxiliary display drivers.
12           This option alone does not add any kernel code.
13
14           If you say N, all options in this submenu will be skipped and disabled.
15
16 config CHARLCD
17         tristate "Character LCD core support" if COMPILE_TEST
18
19 if AUXDISPLAY
20
21 config HD44780
22         tristate "HD44780 Character LCD support"
23         depends on GPIOLIB || COMPILE_TEST
24         select CHARLCD
25         ---help---
26           Enable support for Character LCDs using a HD44780 controller.
27           The LCD is accessible through the /dev/lcd char device (10, 156).
28           This code can either be compiled as a module, or linked into the
29           kernel and started at boot.
30           If you don't understand what all this is about, say N.
31
32 config KS0108
33         tristate "KS0108 LCD Controller"
34         depends on PARPORT_PC
35         default n
36         ---help---
37           If you have a LCD controlled by one or more KS0108
38           controllers, say Y. You will need also another more specific
39           driver for your LCD.
40
41           Depends on Parallel Port support. If you say Y at
42           parport, you will be able to compile this as a module (M)
43           and built-in as well (Y).
44
45           To compile this as a module, choose M here:
46           the module will be called ks0108.
47
48           If unsure, say N.
49
50 config KS0108_PORT
51         hex "Parallel port where the LCD is connected"
52         depends on KS0108
53         default 0x378
54         ---help---
55           The address of the parallel port where the LCD is connected.
56
57           The first  standard parallel port address is 0x378.
58           The second standard parallel port address is 0x278.
59           The third  standard parallel port address is 0x3BC.
60
61           You can specify a different address if you need.
62
63           If you don't know what I'm talking about, load the parport module,
64           and execute "dmesg" or "cat /proc/ioports". You can see there how
65           many parallel ports are present and which address each one has.
66
67           Usually you only need to use 0x378.
68
69           If you compile this as a module, you can still override this
70           using the module parameters.
71
72 config KS0108_DELAY
73         int "Delay between each control writing (microseconds)"
74         depends on KS0108
75         default "2"
76         ---help---
77           Amount of time the ks0108 should wait between each control write
78           to the parallel port.
79
80           If your LCD seems to miss random writings, increment this.
81
82           If you don't know what I'm talking about, ignore it.
83
84           If you compile this as a module, you can still override this
85           value using the module parameters.
86
87 config CFAG12864B
88         tristate "CFAG12864B LCD"
89         depends on X86
90         depends on FB
91         depends on KS0108
92         select FB_SYS_FILLRECT
93         select FB_SYS_COPYAREA
94         select FB_SYS_IMAGEBLIT
95         select FB_SYS_FOPS
96         default n
97         ---help---
98           If you have a Crystalfontz 128x64 2-color LCD, cfag12864b Series,
99           say Y. You also need the ks0108 LCD Controller driver.
100
101           For help about how to wire your LCD to the parallel port,
102           check Documentation/auxdisplay/cfag12864b
103
104           Depends on the x86 arch and the framebuffer support.
105
106           The LCD framebuffer driver can be attached to a console.
107           It will work fine. However, you can't attach it to the fbdev driver
108           of the xorg server.
109
110           To compile this as a module, choose M here:
111           the modules will be called cfag12864b and cfag12864bfb.
112
113           If unsure, say N.
114
115 config CFAG12864B_RATE
116        int "Refresh rate (hertz)"
117         depends on CFAG12864B
118         default "20"
119         ---help---
120           Refresh rate of the LCD.
121
122           As the LCD is not memory mapped, the driver has to make the work by
123           software. This means you should be careful setting this value higher.
124           If your CPUs are really slow or you feel the system is slowed down,
125           decrease the value.
126
127           Be careful modifying this value to a very high value:
128           You can freeze the computer, or the LCD maybe can't draw as fast as you
129           are requesting.
130
131           If you don't know what I'm talking about, ignore it.
132
133           If you compile this as a module, you can still override this
134           value using the module parameters.
135
136 config IMG_ASCII_LCD
137         tristate "Imagination Technologies ASCII LCD Display"
138         default y if MIPS_MALTA || MIPS_SEAD3
139         select SYSCON
140         help
141           Enable this to support the simple ASCII LCD displays found on
142           development boards such as the MIPS Boston, MIPS Malta & MIPS SEAD3
143           from Imagination Technologies.
144
145 config HT16K33
146         tristate "Holtek Ht16K33 LED controller with keyscan"
147         depends on FB && OF && I2C && INPUT
148         select FB_SYS_FOPS
149         select FB_SYS_FILLRECT
150         select FB_SYS_COPYAREA
151         select FB_SYS_IMAGEBLIT
152         select INPUT_MATRIXKMAP
153         select FB_BACKLIGHT
154         help
155           Say yes here to add support for Holtek HT16K33, RAM mapping 16*8
156           LED controller driver with keyscan.
157
158 endif # AUXDISPLAY
159
160 config ARM_CHARLCD
161         bool "ARM Ltd. Character LCD Driver"
162         depends on PLAT_VERSATILE
163         help
164           This is a driver for the character LCD found on the ARM Ltd.
165           Versatile and RealView Platform Baseboards. It doesn't do
166           very much more than display the text "ARM Linux" on the first
167           line and the Linux version on the second line, but that's
168           still useful.
169
170 config PANEL
171         tristate "Parallel port LCD/Keypad Panel support"
172         depends on PARPORT
173         select CHARLCD
174         ---help---
175           Say Y here if you have an HD44780 or KS-0074 LCD connected to your
176           parallel port. This driver also features 4 and 6-key keypads. The LCD
177           is accessible through the /dev/lcd char device (10, 156), and the
178           keypad through /dev/keypad (10, 185). This code can either be
179           compiled as a module, or linked into the kernel and started at boot.
180           If you don't understand what all this is about, say N.
181
182 if PANEL
183
184 config PANEL_PARPORT
185         int "Default parallel port number (0=LPT1)"
186         range 0 255
187         default "0"
188         ---help---
189           This is the index of the parallel port the panel is connected to. One
190           driver instance only supports one parallel port, so if your keypad
191           and LCD are connected to two separate ports, you have to start two
192           modules with different arguments. Numbering starts with '0' for LPT1,
193           and so on.
194
195 config PANEL_PROFILE
196         int "Default panel profile (0-5, 0=custom)"
197         range 0 5
198         default "5"
199         ---help---
200           To ease configuration, the driver supports different configuration
201           profiles for past and recent wirings. These profiles can also be
202           used to define an approximative configuration, completed by a few
203           other options. Here are the profiles :
204
205             0 = custom (see further)
206             1 = 2x16 parallel LCD, old keypad
207             2 = 2x16 serial LCD (KS-0074), new keypad
208             3 = 2x16 parallel LCD (Hantronix), no keypad
209             4 = 2x16 parallel LCD (Nexcom NSA1045) with Nexcom's keypad
210             5 = 2x40 parallel LCD (old one), with old keypad
211
212           Custom configurations allow you to define how your display is
213           wired to the parallel port, and how it works. This is only intended
214           for experts.
215
216 config PANEL_KEYPAD
217         depends on PANEL_PROFILE="0"
218         int "Keypad type (0=none, 1=old 6 keys, 2=new 6 keys, 3=Nexcom 4 keys)"
219         range 0 3
220         default 0
221         ---help---
222           This enables and configures a keypad connected to the parallel port.
223           The keys will be read from character device 10,185. Valid values are :
224
225             0 : do not enable this driver
226             1 : old 6 keys keypad
227             2 : new 6 keys keypad, as used on the server at www.ant-computing.com
228             3 : Nexcom NSA1045's 4 keys keypad
229
230           New profiles can be described in the driver source. The driver also
231           supports simultaneous keys pressed when the keypad supports them.
232
233 config PANEL_LCD
234         depends on PANEL_PROFILE="0"
235         int "LCD type (0=none, 1=custom, 2=old //, 3=ks0074, 4=hantronix, 5=Nexcom)"
236         range 0 5
237         default 0
238         ---help---
239            This enables and configures an LCD connected to the parallel port.
240            The driver includes an interpreter for escape codes starting with
241            '\e[L' which are specific to the LCD, and a few ANSI codes. The
242            driver will be registered as character device 10,156, usually
243            under the name '/dev/lcd'. There are a total of 6 supported types :
244
245              0 : do not enable the driver
246              1 : custom configuration and wiring (see further)
247              2 : 2x16 & 2x40 parallel LCD (old wiring)
248              3 : 2x16 serial LCD (KS-0074 based)
249              4 : 2x16 parallel LCD (Hantronix wiring)
250              5 : 2x16 parallel LCD (Nexcom wiring)
251
252            When type '1' is specified, other options will appear to configure
253            more precise aspects (wiring, dimensions, protocol, ...). Please note
254            that those values changed from the 2.4 driver for better consistency.
255
256 config PANEL_LCD_HEIGHT
257         depends on PANEL_PROFILE="0" && PANEL_LCD="1"
258         int "Number of lines on the LCD (1-2)"
259         range 1 2
260         default 2
261         ---help---
262           This is the number of visible character lines on the LCD in custom profile.
263           It can either be 1 or 2.
264
265 config PANEL_LCD_WIDTH
266         depends on PANEL_PROFILE="0" && PANEL_LCD="1"
267         int "Number of characters per line on the LCD (1-40)"
268         range 1 40
269         default 40
270         ---help---
271           This is the number of characters per line on the LCD in custom profile.
272           Common values are 16,20,24,40.
273
274 config PANEL_LCD_BWIDTH
275         depends on PANEL_PROFILE="0" && PANEL_LCD="1"
276         int "Internal LCD line width (1-40, 40 by default)"
277         range 1 40
278         default 40
279         ---help---
280           Most LCDs use a standard controller which supports hardware lines of 40
281           characters, although sometimes only 16, 20 or 24 of them are really wired
282           to the terminal. This results in some non-visible but addressable characters,
283           and is the case for most parallel LCDs. Other LCDs, and some serial ones,
284           however, use the same line width internally as what is visible. The KS0074
285           for example, uses 16 characters per line for 16 visible characters per line.
286
287           This option lets you configure the value used by your LCD in 'custom' profile.
288           If you don't know, put '40' here.
289
290 config PANEL_LCD_HWIDTH
291         depends on PANEL_PROFILE="0" && PANEL_LCD="1"
292         int "Hardware LCD line width (1-64, 64 by default)"
293         range 1 64
294         default 64
295         ---help---
296           Most LCDs use a single address bit to differentiate line 0 and line 1. Since
297           some of them need to be able to address 40 chars with the lower bits, they
298           often use the immediately superior power of 2, which is 64, to address the
299           next line.
300
301           If you don't know what your LCD uses, in doubt let 16 here for a 2x16, and
302           64 here for a 2x40.
303
304 config PANEL_LCD_CHARSET
305         depends on PANEL_PROFILE="0" && PANEL_LCD="1"
306         int "LCD character set (0=normal, 1=KS0074)"
307         range 0 1
308         default 0
309         ---help---
310           Some controllers such as the KS0074 use a somewhat strange character set
311           where many symbols are at unusual places. The driver knows how to map
312           'standard' ASCII characters to the character sets used by these controllers.
313           Valid values are :
314
315              0 : normal (untranslated) character set
316              1 : KS0074 character set
317
318           If you don't know, use the normal one (0).
319
320 config PANEL_LCD_PROTO
321         depends on PANEL_PROFILE="0" && PANEL_LCD="1"
322         int "LCD communication mode (0=parallel 8 bits, 1=serial)"
323         range 0 1
324         default 0
325         ---help---
326           This driver now supports any serial or parallel LCD wired to a parallel
327           port. But before assigning signals, the driver needs to know if it will
328           be driving a serial LCD or a parallel one. Serial LCDs only use 2 wires
329           (SDA/SCL), while parallel ones use 2 or 3 wires for the control signals
330           (E, RS, sometimes RW), and 4 or 8 for the data. Use 0 here for a 8 bits
331           parallel LCD, and 1 for a serial LCD.
332
333 config PANEL_LCD_PIN_E
334         depends on PANEL_PROFILE="0" && PANEL_LCD="1" && PANEL_LCD_PROTO="0"
335         int "Parallel port pin number & polarity connected to the LCD E signal (-17...17) "
336         range -17 17
337         default 14
338         ---help---
339           This describes the number of the parallel port pin to which the LCD 'E'
340           signal has been connected. It can be :
341
342                   0 : no connection (eg: connected to ground)
343               1..17 : directly connected to any of these pins on the DB25 plug
344             -1..-17 : connected to the same pin through an inverter (eg: transistor).
345
346           Default for the 'E' pin in custom profile is '14' (AUTOFEED).
347
348 config PANEL_LCD_PIN_RS
349         depends on PANEL_PROFILE="0" && PANEL_LCD="1" && PANEL_LCD_PROTO="0"
350         int "Parallel port pin number & polarity connected to the LCD RS signal (-17...17) "
351         range -17 17
352         default 17
353         ---help---
354           This describes the number of the parallel port pin to which the LCD 'RS'
355           signal has been connected. It can be :
356
357                   0 : no connection (eg: connected to ground)
358               1..17 : directly connected to any of these pins on the DB25 plug
359             -1..-17 : connected to the same pin through an inverter (eg: transistor).
360
361           Default for the 'RS' pin in custom profile is '17' (SELECT IN).
362
363 config PANEL_LCD_PIN_RW
364         depends on PANEL_PROFILE="0" && PANEL_LCD="1" && PANEL_LCD_PROTO="0"
365         int "Parallel port pin number & polarity connected to the LCD RW signal (-17...17) "
366         range -17 17
367         default 16
368         ---help---
369           This describes the number of the parallel port pin to which the LCD 'RW'
370           signal has been connected. It can be :
371
372                   0 : no connection (eg: connected to ground)
373               1..17 : directly connected to any of these pins on the DB25 plug
374             -1..-17 : connected to the same pin through an inverter (eg: transistor).
375
376           Default for the 'RW' pin in custom profile is '16' (INIT).
377
378 config PANEL_LCD_PIN_SCL
379         depends on PANEL_PROFILE="0" && PANEL_LCD="1" && PANEL_LCD_PROTO!="0"
380         int "Parallel port pin number & polarity connected to the LCD SCL signal (-17...17) "
381         range -17 17
382         default 1
383         ---help---
384           This describes the number of the parallel port pin to which the serial
385           LCD 'SCL' signal has been connected. It can be :
386
387                   0 : no connection (eg: connected to ground)
388               1..17 : directly connected to any of these pins on the DB25 plug
389             -1..-17 : connected to the same pin through an inverter (eg: transistor).
390
391           Default for the 'SCL' pin in custom profile is '1' (STROBE).
392
393 config PANEL_LCD_PIN_SDA
394         depends on PANEL_PROFILE="0" && PANEL_LCD="1" && PANEL_LCD_PROTO!="0"
395         int "Parallel port pin number & polarity connected to the LCD SDA signal (-17...17) "
396         range -17 17
397         default 2
398         ---help---
399           This describes the number of the parallel port pin to which the serial
400           LCD 'SDA' signal has been connected. It can be :
401
402                   0 : no connection (eg: connected to ground)
403               1..17 : directly connected to any of these pins on the DB25 plug
404             -1..-17 : connected to the same pin through an inverter (eg: transistor).
405
406           Default for the 'SDA' pin in custom profile is '2' (D0).
407
408 config PANEL_LCD_PIN_BL
409         depends on PANEL_PROFILE="0" && PANEL_LCD="1"
410         int "Parallel port pin number & polarity connected to the LCD backlight signal (-17...17) "
411         range -17 17
412         default 0
413         ---help---
414           This describes the number of the parallel port pin to which the LCD 'BL' signal
415           has been connected. It can be :
416
417                   0 : no connection (eg: connected to ground)
418               1..17 : directly connected to any of these pins on the DB25 plug
419             -1..-17 : connected to the same pin through an inverter (eg: transistor).
420
421           Default for the 'BL' pin in custom profile is '0' (uncontrolled).
422
423 config PANEL_CHANGE_MESSAGE
424         bool "Change LCD initialization message ?"
425         default "n"
426         ---help---
427           This allows you to replace the boot message indicating the kernel version
428           and the driver version with a custom message. This is useful on appliances
429           where a simple 'Starting system' message can be enough to stop a customer
430           from worrying.
431
432           If you say 'Y' here, you'll be able to choose a message yourself. Otherwise,
433           say 'N' and keep the default message with the version.
434
435 config PANEL_BOOT_MESSAGE
436         depends on PANEL_CHANGE_MESSAGE="y"
437         string "New initialization message"
438         default ""
439         ---help---
440           This allows you to replace the boot message indicating the kernel version
441           and the driver version with a custom message. This is useful on appliances
442           where a simple 'Starting system' message can be enough to stop a customer
443           from worrying.
444
445           An empty message will only clear the display at driver init time. Any other
446           printf()-formatted message is valid with newline and escape codes.
447
448 endif # PANEL