]> git.kernelconcepts.de Git - karo-tx-linux.git/commitdiff
thermal: rcar_gen3_thermal: Document the R-Car Gen3
authorWolfram Sang <wsa+renesas@sang-engineering.com>
Thu, 22 Dec 2016 10:38:20 +0000 (11:38 +0100)
committerEduardo Valentin <edubezval@gmail.com>
Fri, 20 Jan 2017 04:15:28 +0000 (20:15 -0800)
Signed-off-by: Hien Dang <hien.dang.eb@renesas.com>
Signed-off-by: Khiem Nguyen <khiem.nguyen.xt@renesas.com>
Signed-off-by: Wolfram Sang <wsa+renesas@sang-engineering.com>
Signed-off-by: Niklas Söderlund <niklas.soderlund+renesas@ragnatech.se>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Documentation/devicetree/bindings/thermal/rcar-gen3-thermal.txt [new file with mode: 0644]

diff --git a/Documentation/devicetree/bindings/thermal/rcar-gen3-thermal.txt b/Documentation/devicetree/bindings/thermal/rcar-gen3-thermal.txt
new file mode 100644 (file)
index 0000000..07a9713
--- /dev/null
@@ -0,0 +1,56 @@
+* DT bindings for Renesas R-Car Gen3 Thermal Sensor driver
+
+On R-Car Gen3 SoCs, the thermal sensor controllers (TSC) control the thermal
+sensors (THS) which are the analog circuits for measuring temperature (Tj)
+inside the LSI.
+
+Required properties:
+- compatible           : "renesas,<soctype>-thermal",
+                         Examples with soctypes are:
+                           - "renesas,r8a7795-thermal" (R-Car H3)
+                           - "renesas,r8a7796-thermal" (R-Car M3-W)
+- reg                  : Address ranges of the thermal registers. Each sensor
+                         needs one address range. Sorting must be done in
+                         increasing order according to datasheet, i.e.
+                         TSC1, TSC2, ...
+- clocks               : Must contain a reference to the functional clock.
+- #thermal-sensor-cells : must be <1>.
+
+Optional properties:
+
+- interrupts           : interrupts routed to the TSC (3 for H3 and M3-W)
+- power-domain         : Must contain a reference to the power domain. This
+                         property is mandatory if the thermal sensor instance
+                         is part of a controllable power domain.
+
+Example:
+
+       tsc: thermal@e6198000 {
+               compatible = "renesas,r8a7795-thermal";
+               reg = <0 0xe6198000 0 0x68>,
+                     <0 0xe61a0000 0 0x5c>,
+                     <0 0xe61a8000 0 0x5c>;
+               interrupts = <GIC_SPI 67 IRQ_TYPE_LEVEL_HIGH>,
+                            <GIC_SPI 68 IRQ_TYPE_LEVEL_HIGH>,
+                            <GIC_SPI 69 IRQ_TYPE_LEVEL_HIGH>;
+               clocks = <&cpg CPG_MOD 522>;
+               power-domains = <&sysc R8A7795_PD_ALWAYS_ON>;
+               #thermal-sensor-cells = <1>;
+               status = "okay";
+       };
+
+       thermal-zones {
+               sensor_thermal1: sensor-thermal1 {
+                       polling-delay-passive = <250>;
+                       polling-delay = <1000>;
+                       thermal-sensors = <&tsc 0>;
+
+                       trips {
+                               sensor1_crit: sensor1-crit {
+                                       temperature = <90000>;
+                                       hysteresis = <2000>;
+                                       type = "critical";
+                               };
+                       };
+               };
+       };