]> git.kernelconcepts.de Git - karo-tx-linux.git/blobdiff - drivers/thermal/cpu_cooling.c
Merge tag 'master-2014-12-08' of git://git.kernel.org/pub/scm/linux/kernel/git/linvil...
[karo-tx-linux.git] / drivers / thermal / cpu_cooling.c
index 1ab0018271c5c622c0b7556fb92a3a1d9ad38e5b..ad09e51ffae4d097109241d9a19b97c97858109b 100644 (file)
@@ -50,15 +50,14 @@ struct cpufreq_cooling_device {
        unsigned int cpufreq_state;
        unsigned int cpufreq_val;
        struct cpumask allowed_cpus;
+       struct list_head node;
 };
 static DEFINE_IDR(cpufreq_idr);
 static DEFINE_MUTEX(cooling_cpufreq_lock);
 
 static unsigned int cpufreq_dev_count;
 
-/* notify_table passes value to the CPUFREQ_ADJUST callback function. */
-#define NOTIFY_INVALID NULL
-static struct cpufreq_cooling_device *notify_device;
+static LIST_HEAD(cpufreq_dev_list);
 
 /**
  * get_idr - function to get a unique id.
@@ -287,15 +286,12 @@ static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device,
 
        cpufreq_device->cpufreq_state = cooling_state;
        cpufreq_device->cpufreq_val = clip_freq;
-       notify_device = cpufreq_device;
 
        for_each_cpu(cpuid, mask) {
                if (is_cpufreq_valid(cpuid))
                        cpufreq_update_policy(cpuid);
        }
 
-       notify_device = NOTIFY_INVALID;
-
        return 0;
 }
 
@@ -316,21 +312,28 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb,
 {
        struct cpufreq_policy *policy = data;
        unsigned long max_freq = 0;
+       struct cpufreq_cooling_device *cpufreq_dev;
 
-       if (event != CPUFREQ_ADJUST || notify_device == NOTIFY_INVALID)
+       if (event != CPUFREQ_ADJUST)
                return 0;
 
-       if (cpumask_test_cpu(policy->cpu, &notify_device->allowed_cpus))
-               max_freq = notify_device->cpufreq_val;
-       else
-               return 0;
+       mutex_lock(&cooling_cpufreq_lock);
+       list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
+               if (!cpumask_test_cpu(policy->cpu,
+                                       &cpufreq_dev->allowed_cpus))
+                       continue;
+
+               if (!cpufreq_dev->cpufreq_val)
+                       cpufreq_dev->cpufreq_val = get_cpu_frequency(
+                                       cpumask_any(&cpufreq_dev->allowed_cpus),
+                                       cpufreq_dev->cpufreq_state);
 
-       /* Never exceed user_policy.max */
-       if (max_freq > policy->user_policy.max)
-               max_freq = policy->user_policy.max;
+               max_freq = cpufreq_dev->cpufreq_val;
 
-       if (policy->max != max_freq)
-               cpufreq_verify_within_limits(policy, 0, max_freq);
+               if (policy->max != max_freq)
+                       cpufreq_verify_within_limits(policy, 0, max_freq);
+       }
+       mutex_unlock(&cooling_cpufreq_lock);
 
        return 0;
 }
@@ -486,6 +489,7 @@ __cpufreq_cooling_register(struct device_node *np,
                cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
                                          CPUFREQ_POLICY_NOTIFIER);
        cpufreq_dev_count++;
+       list_add(&cpufreq_dev->node, &cpufreq_dev_list);
 
        mutex_unlock(&cooling_cpufreq_lock);
 
@@ -549,6 +553,7 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
 
        cpufreq_dev = cdev->devdata;
        mutex_lock(&cooling_cpufreq_lock);
+       list_del(&cpufreq_dev->node);
        cpufreq_dev_count--;
 
        /* Unregister the notifier for the last cpufreq cooling device */