MLK-10106 thermal: imx: correct clk enable and thermal sensor init sequence
authorAnson Huang <b20788@freescale.com>
Fri, 16 Jan 2015 13:16:35 +0000 (21:16 +0800)
committerBai Ping <b51503@freescale.com>
Fri, 16 Jan 2015 16:03:57 +0000 (00:03 +0800)
thermal sensor's irq init should be done after clk enabled, also,
the low alarm value should be set correctly before clearing its
irq status.

Signed-off-by: Anson Huang <b20788@freescale.com>
Signed-off-by: Bai Ping <b51503@freescale.com>
drivers/thermal/imx_thermal.c

index bf886c4a7f901fc858bc6e1f65792d5429b1a558..37f3be286335b02f55dfa6e37cfde747b6e93193 100644 (file)
@@ -538,31 +538,39 @@ static int imx_thermal_probe(struct platform_device *pdev)
 
        data->socdata = of_id->data;
 
+       data->thermal_clk = devm_clk_get(&pdev->dev, NULL);
+       if (IS_ERR(data->thermal_clk)) {
+               dev_warn(&pdev->dev, "failed to get thermal clk!\n");
+       } else {
+               /*
+                * Thermal sensor needs clk on to get correct value, normally
+                * we should enable its clk before taking measurement and disable
+                * clk after measurement is done, but if alarm function is enabled,
+                * hardware will auto measure the temperature periodically, so we
+                * need to keep the clk always on for alarm function.
+                */
+               ret = clk_prepare_enable(data->thermal_clk);
+               if (ret)
+                       dev_warn(&pdev->dev, "failed to enable thermal clk: %d\n", ret);
+       }
+
        /* make sure the IRQ flag is clear before enable irq */
        regmap_write(map, MISC1 + REG_CLR, MISC1_IRQ_TEMPHIGH);
        if (data->socdata->version == TEMPMON_V2) {
-               regmap_write(map, MISC1 + REG_CLR, MISC1_IRQ_TEMPLOW |
-                       MISC1_IRQ_TEMPPANIC);
                /*
                 * reset value of LOW ALARM is incorrect, set it to lowest
                 * value to avoid false trigger of low alarm.
                 */
                regmap_write(map, TEMPSENSE2 + REG_SET,
                        TEMPSENSE2_LOW_VALUE_MASK);
+               regmap_write(map, MISC1 + REG_CLR, MISC1_IRQ_TEMPLOW |
+                       MISC1_IRQ_TEMPPANIC);
        }
 
        data->irq = platform_get_irq(pdev, 0);
        if (data->irq < 0)
                return data->irq;
 
-       ret = devm_request_threaded_irq(&pdev->dev, data->irq,
-                       imx_thermal_alarm_irq, imx_thermal_alarm_irq_thread,
-                       0, "imx_thermal", data);
-       if (ret < 0) {
-               dev_err(&pdev->dev, "failed to request alarm irq: %d\n", ret);
-               return ret;
-       }
-
        platform_set_drvdata(pdev, data);
 
        ret = imx_get_sensor_data(pdev);
@@ -610,22 +618,6 @@ static int imx_thermal_probe(struct platform_device *pdev)
                return ret;
        }
 
-       data->thermal_clk = devm_clk_get(&pdev->dev, NULL);
-       if (IS_ERR(data->thermal_clk)) {
-               dev_warn(&pdev->dev, "failed to get thermal clk!\n");
-       } else {
-               /*
-                * Thermal sensor needs clk on to get correct value, normally
-                * we should enable its clk before taking measurement and disable
-                * clk after measurement is done, but if alarm function is enabled,
-                * hardware will auto measure the temperature periodically, so we
-                * need to keep the clk always on for alarm function.
-                */
-               ret = clk_prepare_enable(data->thermal_clk);
-               if (ret)
-                       dev_warn(&pdev->dev, "failed to enable thermal clk: %d\n", ret);
-       }
-
        /* Enable measurements at ~ 10 Hz */
        regmap_write(map, TEMPSENSE1 + REG_CLR, TEMPSENSE1_MEASURE_FREQ);
        measure_freq = DIV_ROUND_UP(32768, 10); /* 10 Hz */
@@ -638,6 +630,13 @@ static int imx_thermal_probe(struct platform_device *pdev)
        regmap_write(map, TEMPSENSE0 + REG_CLR, TEMPSENSE0_POWER_DOWN);
        regmap_write(map, TEMPSENSE0 + REG_SET, TEMPSENSE0_MEASURE_TEMP);
 
+       ret = devm_request_threaded_irq(&pdev->dev, data->irq,
+                       imx_thermal_alarm_irq, imx_thermal_alarm_irq_thread,
+                       0, "imx_thermal", data);
+       if (ret < 0) {
+               dev_err(&pdev->dev, "failed to request alarm irq: %d\n", ret);
+               return ret;
+       }
        data->irq_enabled = true;
        data->mode = THERMAL_DEVICE_ENABLED;
        /* register the busfreq notifier called in low bus freq */