From a9003187a984ea835b5533165d97733303c5399e Mon Sep 17 00:00:00 2001 From: Geert Uytterhoeven Date: Tue, 31 May 2016 11:08:45 +0200 Subject: [PATCH] arm64: dts: r8a7796: Use SYSC "always-on" PM Domain Hook up all devices that are part of the CPG/MSSR Clock Domain to the SYSC "always-on" PM Domain, for a more consistent device-power-area description in DT. Signed-off-by: Geert Uytterhoeven Signed-off-by: Simon Horman --- arch/arm64/boot/dts/renesas/r8a7796.dtsi | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/arch/arm64/boot/dts/renesas/r8a7796.dtsi b/arch/arm64/boot/dts/renesas/r8a7796.dtsi index 85f0843ddd87..fab61eddede3 100644 --- a/arch/arm64/boot/dts/renesas/r8a7796.dtsi +++ b/arch/arm64/boot/dts/renesas/r8a7796.dtsi @@ -122,7 +122,7 @@ <&cpg CPG_CORE R8A7796_CLK_S3D1>, <&scif_clk>; clock-names = "fck", "brg_int", "scif_clk"; - power-domains = <&cpg>; + power-domains = <&sysc R8A7796_PD_ALWAYS_ON>; status = "disabled"; }; }; -- 2.39.2