/* reset time, capture current incrementer value time */
gd->lastinc = readl(&timer_base->tcrr) / (TIMER_CLOCK / CONFIG_SYS_HZ);
- gd->tbl = 0; /* start "advancing" time stamp from 0 */
+ gd->arch.tbl = 0; /* start "advancing" time stamp from 0 */
return 0;
}
/* current tick value */
ulong now = readl(&timer_base->tcrr) / (TIMER_CLOCK / CONFIG_SYS_HZ);
- if (now >= gd->lastinc) /* normal mode (non roll) */
+ if (now >= gd->lastinc) { /* normal mode (non roll) */
/* move stamp fordward with absoulte diff ticks */
- gd->tbl += (now - gd->lastinc);
- else /* we have rollover of incrementer */
- gd->tbl += ((TIMER_LOAD_VAL / (TIMER_CLOCK / CONFIG_SYS_HZ))
- - gd->lastinc) + now;
+ gd->arch.tbl += (now - gd->lastinc);
+ } else { /* we have rollover of incrementer */
+ gd->arch.tbl += ((TIMER_LOAD_VAL / (TIMER_CLOCK /
+ CONFIG_SYS_HZ)) - gd->lastinc) + now;
+ }
gd->lastinc = now;
- return gd->tbl;
+ return gd->arch.tbl;
}
/*