]> git.kernelconcepts.de Git - karo-tx-linux.git/blob - Documentation/thermal/sysfs-api.txt
Thermal: Documentation update
[karo-tx-linux.git] / Documentation / thermal / sysfs-api.txt
1 Generic Thermal Sysfs driver How To
2 ===================================
3
4 Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>
5
6 Updated: 2 January 2008
7
8 Copyright (c)  2008 Intel Corporation
9
10
11 0. Introduction
12
13 The generic thermal sysfs provides a set of interfaces for thermal zone
14 devices (sensors) and thermal cooling devices (fan, processor...) to register
15 with the thermal management solution and to be a part of it.
16
17 This how-to focuses on enabling new thermal zone and cooling devices to
18 participate in thermal management.
19 This solution is platform independent and any type of thermal zone devices
20 and cooling devices should be able to make use of the infrastructure.
21
22 The main task of the thermal sysfs driver is to expose thermal zone attributes
23 as well as cooling device attributes to the user space.
24 An intelligent thermal management application can make decisions based on
25 inputs from thermal zone attributes (the current temperature and trip point
26 temperature) and throttle appropriate devices.
27
28 [0-*]   denotes any positive number starting from 0
29 [1-*]   denotes any positive number starting from 1
30
31 1. thermal sysfs driver interface functions
32
33 1.1 thermal zone device interface
34 1.1.1 struct thermal_zone_device *thermal_zone_device_register(char *name,
35                 int trips, int mask, void *devdata,
36                 struct thermal_zone_device_ops *ops)
37
38     This interface function adds a new thermal zone device (sensor) to
39     /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
40     thermal cooling devices registered at the same time.
41
42     name: the thermal zone name.
43     trips: the total number of trip points this thermal zone supports.
44     mask: Bit string: If 'n'th bit is set, then trip point 'n' is writeable.
45     devdata: device private data
46     ops: thermal zone device call-backs.
47         .bind: bind the thermal zone device with a thermal cooling device.
48         .unbind: unbind the thermal zone device with a thermal cooling device.
49         .get_temp: get the current temperature of the thermal zone.
50         .get_mode: get the current mode (enabled/disabled) of the thermal zone.
51             - "enabled" means the kernel thermal management is enabled.
52             - "disabled" will prevent kernel thermal driver action upon trip points
53               so that user applications can take charge of thermal management.
54         .set_mode: set the mode (enabled/disabled) of the thermal zone.
55         .get_trip_type: get the type of certain trip point.
56         .get_trip_temp: get the temperature above which the certain trip point
57                         will be fired.
58
59 1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)
60
61     This interface function removes the thermal zone device.
62     It deletes the corresponding entry form /sys/class/thermal folder and
63     unbind all the thermal cooling devices it uses.
64
65 1.2 thermal cooling device interface
66 1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
67                 void *devdata, struct thermal_cooling_device_ops *)
68
69     This interface function adds a new thermal cooling device (fan/processor/...)
70     to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
71     to all the thermal zone devices register at the same time.
72     name: the cooling device name.
73     devdata: device private data.
74     ops: thermal cooling devices call-backs.
75         .get_max_state: get the Maximum throttle state of the cooling device.
76         .get_cur_state: get the Current throttle state of the cooling device.
77         .set_cur_state: set the Current throttle state of the cooling device.
78
79 1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
80
81     This interface function remove the thermal cooling device.
82     It deletes the corresponding entry form /sys/class/thermal folder and
83     unbind itself from all the thermal zone devices using it.
84
85 1.3 interface for binding a thermal zone device with a thermal cooling device
86 1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
87                 int trip, struct thermal_cooling_device *cdev);
88
89     This interface function bind a thermal cooling device to the certain trip
90     point of a thermal zone device.
91     This function is usually called in the thermal zone device .bind callback.
92     tz: the thermal zone device
93     cdev: thermal cooling device
94     trip: indicates which trip point the cooling devices is associated with
95           in this thermal zone.
96
97 1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
98                 int trip, struct thermal_cooling_device *cdev);
99
100     This interface function unbind a thermal cooling device from the certain
101     trip point of a thermal zone device. This function is usually called in
102     the thermal zone device .unbind callback.
103     tz: the thermal zone device
104     cdev: thermal cooling device
105     trip: indicates which trip point the cooling devices is associated with
106           in this thermal zone.
107
108 2. sysfs attributes structure
109
110 RO      read only value
111 RW      read/write value
112
113 Thermal sysfs attributes will be represented under /sys/class/thermal.
114 Hwmon sysfs I/F extension is also available under /sys/class/hwmon
115 if hwmon is compiled in or built as a module.
116
117 Thermal zone device sys I/F, created once it's registered:
118 /sys/class/thermal/thermal_zone[0-*]:
119     |---type:                   Type of the thermal zone
120     |---temp:                   Current temperature
121     |---mode:                   Working mode of the thermal zone
122     |---trip_point_[0-*]_temp:  Trip point temperature
123     |---trip_point_[0-*]_type:  Trip point type
124     |---trip_point_[0-*]_hyst:  Hysteresis value for this trip point
125
126 Thermal cooling device sys I/F, created once it's registered:
127 /sys/class/thermal/cooling_device[0-*]:
128     |---type:                   Type of the cooling device(processor/fan/...)
129     |---max_state:              Maximum cooling state of the cooling device
130     |---cur_state:              Current cooling state of the cooling device
131
132
133 Then next two dynamic attributes are created/removed in pairs. They represent
134 the relationship between a thermal zone and its associated cooling device.
135 They are created/removed for each successful execution of
136 thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device.
137
138 /sys/class/thermal/thermal_zone[0-*]:
139     |---cdev[0-*]:              [0-*]th cooling device in current thermal zone
140     |---cdev[0-*]_trip_point:   Trip point that cdev[0-*] is associated with
141
142 Besides the thermal zone device sysfs I/F and cooling device sysfs I/F,
143 the generic thermal driver also creates a hwmon sysfs I/F for each _type_
144 of thermal zone device. E.g. the generic thermal driver registers one hwmon
145 class device and build the associated hwmon sysfs I/F for all the registered
146 ACPI thermal zones.
147
148 /sys/class/hwmon/hwmon[0-*]:
149     |---name:                   The type of the thermal zone devices
150     |---temp[1-*]_input:        The current temperature of thermal zone [1-*]
151     |---temp[1-*]_critical:     The critical trip point of thermal zone [1-*]
152
153 Please read Documentation/hwmon/sysfs-interface for additional information.
154
155 ***************************
156 * Thermal zone attributes *
157 ***************************
158
159 type
160         Strings which represent the thermal zone type.
161         This is given by thermal zone driver as part of registration.
162         E.g: "acpitz" indicates it's an ACPI thermal device.
163         In order to keep it consistent with hwmon sys attribute; this should
164         be a short, lowercase string, not containing spaces nor dashes.
165         RO, Required
166
167 temp
168         Current temperature as reported by thermal zone (sensor).
169         Unit: millidegree Celsius
170         RO, Required
171
172 mode
173         One of the predefined values in [enabled, disabled].
174         This file gives information about the algorithm that is currently
175         managing the thermal zone. It can be either default kernel based
176         algorithm or user space application.
177         enabled         = enable Kernel Thermal management.
178         disabled        = Preventing kernel thermal zone driver actions upon
179                           trip points so that user application can take full
180                           charge of the thermal management.
181         RW, Optional
182
183 trip_point_[0-*]_temp
184         The temperature above which trip point will be fired.
185         Unit: millidegree Celsius
186         RO, Optional
187
188 trip_point_[0-*]_type
189         Strings which indicate the type of the trip point.
190         E.g. it can be one of critical, hot, passive, active[0-*] for ACPI
191         thermal zone.
192         RO, Optional
193
194 trip_point_[0-*]_hyst
195         The hysteresis value for a trip point, represented as an integer
196         Unit: Celsius
197         RW, Optional
198
199 cdev[0-*]
200         Sysfs link to the thermal cooling device node where the sys I/F
201         for cooling device throttling control represents.
202         RO, Optional
203
204 cdev[0-*]_trip_point
205         The trip point with which cdev[0-*] is associated in this thermal
206         zone; -1 means the cooling device is not associated with any trip
207         point.
208         RO, Optional
209
210 passive
211         Attribute is only present for zones in which the passive cooling
212         policy is not supported by native thermal driver. Default is zero
213         and can be set to a temperature (in millidegrees) to enable a
214         passive trip point for the zone. Activation is done by polling with
215         an interval of 1 second.
216         Unit: millidegrees Celsius
217         Valid values: 0 (disabled) or greater than 1000
218         RW, Optional
219
220 *****************************
221 * Cooling device attributes *
222 *****************************
223
224 type
225         String which represents the type of device, e.g:
226         - for generic ACPI: should be "Fan", "Processor" or "LCD"
227         - for memory controller device on intel_menlow platform:
228           should be "Memory controller".
229         RO, Required
230
231 max_state
232         The maximum permissible cooling state of this cooling device.
233         RO, Required
234
235 cur_state
236         The current cooling state of this cooling device.
237         The value can any integer numbers between 0 and max_state:
238         - cur_state == 0 means no cooling
239         - cur_state == max_state means the maximum cooling.
240         RW, Required
241
242 3. A simple implementation
243
244 ACPI thermal zone may support multiple trip points like critical, hot,
245 passive, active. If an ACPI thermal zone supports critical, passive,
246 active[0] and active[1] at the same time, it may register itself as a
247 thermal_zone_device (thermal_zone1) with 4 trip points in all.
248 It has one processor and one fan, which are both registered as
249 thermal_cooling_device.
250
251 If the processor is listed in _PSL method, and the fan is listed in _AL0
252 method, the sys I/F structure will be built like this:
253
254 /sys/class/thermal:
255
256 |thermal_zone1:
257     |---type:                   acpitz
258     |---temp:                   37000
259     |---mode:                   enabled
260     |---trip_point_0_temp:      100000
261     |---trip_point_0_type:      critical
262     |---trip_point_1_temp:      80000
263     |---trip_point_1_type:      passive
264     |---trip_point_2_temp:      70000
265     |---trip_point_2_type:      active0
266     |---trip_point_3_temp:      60000
267     |---trip_point_3_type:      active1
268     |---cdev0:                  --->/sys/class/thermal/cooling_device0
269     |---cdev0_trip_point:       1       /* cdev0 can be used for passive */
270     |---cdev1:                  --->/sys/class/thermal/cooling_device3
271     |---cdev1_trip_point:       2       /* cdev1 can be used for active[0]*/
272
273 |cooling_device0:
274     |---type:                   Processor
275     |---max_state:              8
276     |---cur_state:              0
277
278 |cooling_device3:
279     |---type:                   Fan
280     |---max_state:              2
281     |---cur_state:              0
282
283 /sys/class/hwmon:
284
285 |hwmon0:
286     |---name:                   acpitz
287     |---temp1_input:            37000
288     |---temp1_crit:             100000
289
290 4. Event Notification
291
292 The framework includes a simple notification mechanism, in the form of a
293 netlink event. Netlink socket initialization is done during the _init_
294 of the framework. Drivers which intend to use the notification mechanism
295 just need to call thermal_generate_netlink_event() with two arguments viz
296 (originator, event). Typically the originator will be an integer assigned
297 to a thermal_zone_device when it registers itself with the framework. The
298 event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,
299 THERMAL_DEV_FAULT}. Notification can be sent when the current temperature
300 crosses any of the configured thresholds.